section 23 52 39 fire-tube boilers - whole building ?

SECTION 23 52 39 FIRE-TUBE BOILERS - Whole Building ?

Agent and completed by the contractor, signed by a qualified technician ... Wet back boilers are specified because ... high pressure steam boiler. Three or four pass wet back design with internal furnace located below center of boiler shell. Designed for natural gas and No. 2 fuel oil firing. 02-01-15 .

Get a Quote
horizontal dry back boiler agen

horizontal dry back boiler Agen

WNS Three Pass Wet Back Oil/Gas Fired Steam Boilers . WNS-type oil (gas) boiler is a horizontal internal combustion three pass fire tube boilers. Furnace with bias wet back structure, high temperature gas erosion followed by the second and third return pipe, and then, after smoke from the room through the chimney into the atmosphere. Get A Quote

Get a Quote
wet back design boiler for sale philippin

wet back design boiler for sale philippin

ZOZEN boiler covers an area of 150 thousand square meters, with an annual production capacity of 2000 industrial boilers and 25000 tons of steam. Our products have been sold to more than 100 countries and regions and set up offices in many countries to ensure that they serve customers at the first time. ... wet back design boiler for sale ...

Get a Quote
scotch marine firetube boiler 3-pass | euro seri

Scotch Marine Firetube Boiler 3-Pass | Euro Seri

Boiler Design. Three-Pass "Scotch Marine" Firetube design with stress relieving "Wetback" construction. Pressure designs for steam are 15-300 psi. 100-600 hp. 250 psi. max. for 700-1500 hp. and 200 psi. max. for 1800-2000 hp. Hot Water pressures models are from 30-160 psi. High pressure, high temperature Section I hot water boilers available.

Get a Quote
wet back steam boil

wet back steam boil

Why Our Boilers Are Designed As Wet-Back Boilers: Dry-Back. WNS gas and oil fired boiler has a full wet back radiant heat transfer area that promotes superior internal water circulation and rapid heat absorption, rear tube sheet, and allows tubes to expand and contract at …

Get a Quote
bt product template – boilertroni

BT Product Template – Boilertroni

Wet back design eliminates, costly deteriorating refractory rear doors and baffles between flue gas passes. Enquire Now. Enquire Now. Four Pass Packaged Scotch Marine High-Pressure Boilers…

Get a Quote
steam boiler - wet back design gas fired boiler .

Steam Boiler - Wet Back Design Gas Fired Boiler .

Steam Boiler Offering you a complete choice of products which include wet back design gas fired boiler, agro waste fired steam boiler, three pass steam boiler, fully automatic steam boiler, urjex make hsd oil fired steam boiler and fluidized bed combustion boiler.

Get a Quote
horizontal style 3 pass wet back boil

Horizontal Style 3 Pass Wet Back Boil

WNS series boiler is well known as a horizontal style three pass wet back boiler.This type boiler used widely in industries and can be designed as steam boiler or hot water boiler according customer inquiry. The fuel of WNS series horizontal style 3 pass wet back boiler can be oil or gas,which is fast-loading internal combustion three return fired tube boiler.

Get a Quote
wet back design boil

wet back design boil

Why we design wet-back boilers Those frustrating problems brought by dry-back boilers can be resolved by our WNS Wet-back designed boilers. WNS gas and oil fired boiler has a full wet back radiant heat transfer area that promotes superior internal water circulation and rapid heat absorption, rear tube sheet, and allows tubes to expand and ...

Get a Quote
why our boilers are designed as wet-back boilers: dry-back .

Why Our Boilers Are Designed As Wet-Back Boilers: Dry-Back .

WNS gas and oil fired boiler has a full wet back radiant heat transfer area that promotes superior internal water circulation and rapid heat absorption, rear tube sheet, and allows tubes to expand and contract at its own rate without tube sheet stress. The only rear refractory is a man way plug which allows access to the furnace for inspection.

Get a Quote
package boilers, watertube boilers, utility boilers - john .

Package Boilers, Watertube Boilers, Utility Boilers - John .

Three-pass, conventional, wet-back design incorporating latest spiral-tube technology with heat transfer up to 100% greater than normal plain tubes; High thermal efficiency of 85% with NCV 15 800 kJ/kg; Boiler rating can be achieved with wood moisture content up to 25%

Get a Quote
cleaver-brooks - complete boiler room solutio

Cleaver-Brooks - Complete Boiler Room Solutio

The design pressure for firetube boilers can go as high as 350 psig, but typically these boilers are in the 150 to 250 psig range. In sizes exceeding 800 to 900 BHP, the wetback design is used because at this size, the refractory rear door on a dryback boiler is too big and heavy to manually maneuver.

Get a Quote
scotch marine boiler - wikiped

Scotch marine boiler - Wikiped

One interesting variant of the dry-back design has been a patent for burning ash-prone fuels. The rear of the combustion chamber is used as an access point for an ash separator, removing the ash before the small-diameter tubes. Double-ended. The double-ended design places two boilers back-to-back, removing the rear wall of the boiler shell.

Get a Quote
wet back boiler suppli

wet back boiler suppli

The wet back boiler design uses separate tube sheets between tube passes which can be more forgiving with load changes. Wetback firetube boilers offer a more optimal functional footprint, with lift off or split-hinged doors that require no cool-down period and can be opened immediately. While there is no expensive refractory to maintain

Get a Quote
wetback and dryback boilers compared | lathrop trotter .

Wetback and Dryback Boilers Compared | Lathrop Trotter .

The wetback boiler has a rear wall that is surrounded by water, while the rear wall of a dryback boiler is lined with refractory. Since the heat from combustion is used for heating water, the wetback boiler design can be considered more efficient than the dryback boiler. Wetback and Dryback Boilers Characteristics Compared

Get a Quote
boiler – fundamentals and best practic

Boiler – Fundamentals and Best Practic

Fire Tube Boilers Also referred to as smoke tube boilers, shell boilers, package boilers Multiple gas paths - 2, 3 and 4 pass Internal furnace or fire box as the 1st pass Dry back or wet back design Single fuel or dual fuel design Little or no steam separation equipment

Get a Quote
solving small constraint problems in wet back boilers .

Solving Small Constraint Problems In Wet Back Boilers .

The design of the wet back boiler can be frustrating for Boilermakers due to the limited access to install tubes in the combustion return area of the boiler. The limited space in wet back boilers makes it necessary to choose alternative methods of tube installation. Depending upon the physical size of the Boilermaker and the power source to ...

Get a Quote
detail of wet back boil

detail of wet back boil

These boilers are three pass, wet-back design principle. Learn More. Manufacturer of Industrial Steam Boiler & Waste Heat Recovery . Solid Fuel Fired-wet Back Boiler With Waste Heat Recoveries-2000 Kg Per Hour we provide our customers with design and detail manufacturing drawings for in-house .

Get a Quote
wetback vs. dryback firetube boiler | cti controltech .

Wetback vs. Dryback Firetube Boiler | CTI Controltech .

The "wet" and "dry" designation indicates whether the firetubes, as they extend to the rear end of the boiler, discharge the hot gases into a reversing chamber surrounded by boiler water (wet) or partially isolated from it (dry).

Get a Quote
wetback vs dryback firetube boiler desi

Wetback vs Dryback firetube boiler desi

The wetback boiler design features a reversal chamber that is jacketed, or completely surrounded by water, which is used to direct flue gasses from the furnace to the tube banks. The surrounding water absorbs burner heat, helping improve operating efficiency as heat from combustion goes directly into evenly heating water instead of refractory.

Get a Quote
4 different designs of the fire tube boiler: which is best ...

4 Different Designs of the Fire Tube Boiler: Which Is Best ...

Horizontal Return Tubular Fire Tube Boiler. As one of the oldest and most simple designs for …

Wetback Systems | Hot Water Cylinders LTD New Zeala

Horizontal Return Tubular Fire Tube Boiler. As one of the oldest and most simple designs for … Some Essentials in the design of the flow and return pipes when it comes to wetbacks: Pipes connecting the wetback and the storage vessel must have adequate rise and fall. This will allow convectional flow and prevent air locks. G12 AS1 states a minimum of 1 in 7 slope to ensure heat will transfer between wetback and storage heater by thermo ...

Get a Quote